Implement --version switch
[infoex-autowx.git] / infoex-autowx.py
index 3d8762c81b58c97eeecc8af10583a835435801c9..442376bafcd703ab288cfe3150947c5e3157365b 100755 (executable)
@@ -2,14 +2,15 @@
 # -*- coding: utf-8 -*-
 
 """
-InfoEx <-> NRCS Auto Wx implementation
+InfoEx <-> NRCS/MesoWest Auto Wx implementation
 Alexander Vasarab
 Wylark Mountaineering LLC
 
-Version 1.0.0
+Version 2.0.0
 
-This program fetches data from an NRCS SNOTEL site and pushes it to
-InfoEx using the new automated weather system implementation.
+This program fetches data from either an NRCS SNOTEL site or MesoWest
+weather station and pushes it to InfoEx using the new automated weather
+system implementation.
 
 It is designed to be run hourly, and it asks for the last three hours
 of data of each desired type, and selects the most recent one. This
@@ -41,6 +42,8 @@ import zeep
 import zeep.cache
 import zeep.transports
 
+__version__ = '2.0.0'
+
 log = logging.getLogger(__name__)
 log.setLevel(logging.DEBUG)
 
@@ -56,20 +59,32 @@ except:
     log.addHandler(handler)
 
 parser = OptionParser()
+
 parser.add_option("--config",
     dest="config",
     metavar="FILE",
     help="location of config file")
+
 parser.add_option("--dry-run",
     action="store_true",
     dest="dry_run",
     default=False,
     help="fetch data but don't upload to InfoEx")
 
+parser.add_option("--version",
+    action="store_true",
+    dest="show_version",
+    default=False,
+    help="show program version and exit")
+
 (options, args) = parser.parse_args()
 
 config = configparser.ConfigParser(allow_no_value=False)
 
+if options.show_version:
+    print("%s - %s" % (os.path.basename(__file__), __version__))
+    sys.exit(0)
+
 if not options.config:
     print("Please specify a configuration file via --config.")
     sys.exit(1)
@@ -109,6 +124,11 @@ try:
                     'PREC'  # PRECIPITATION ACCUMULATION (in)
                     ]
 
+        # XXX: For NRCS, we're manually overriding units for now! Once
+        #      unit conversion is supported for NRCS, REMOVE THIS!
+        if 'units' not in data:
+            data['units'] = 'imperial'
+
     if data['provider'] == 'mesowest':
         data['source'] = 'https://api.synopticdata.com/v2/stations/timeseries'
         data['station_id'] = config['station']['station_id']
@@ -189,10 +209,35 @@ if data['provider'] == 'nrcs':
     iemap['PREC'] = 'precipitationGauge'
     iemap['TOBS'] = 'tempPres'
     iemap['SNWD'] = 'hS'
+    iemap['PRES'] = 'baro'
+    iemap['RHUM'] = 'rH'
+    iemap['WSPD'] = 'windSpeedNum'
+    iemap['WDIR'] = 'windDirectionNum'
+    # unsupported by NRCS:
+    # windGustSpeedNum
 elif data['provider'] == 'mesowest':
     iemap['precip_accum'] = 'precipitationGauge'
     iemap['air_temp'] = 'tempPres'
     iemap['snow_depth'] = 'hS'
+    iemap['pressure'] = 'baro'
+    iemap['relative_humidity'] = 'rH'
+    iemap['wind_speed'] = 'windSpeedNum'
+    iemap['wind_direction'] = 'windDirectionNum'
+    iemap['wind_gust'] = 'windGustSpeedNum'
+
+# override units if user selected metric
+#
+# NOTE: to update this, use the fmap<->final_data mapping laid out above
+#
+# NOTE: this only 'works' with MesoWest for now, as the MesoWest API
+#       itself handles the unit conversion; in the future, we will also
+#       support NRCS unit conversion, but this must be done by this
+#       program.
+if data['units'] == 'metric':
+    final_data[fmap['tempPresUnit']] = 'C'
+    final_data[fmap['hsUnit']] = 'm'
+    final_data[fmap['windSpeedUnit']] = 'm/s'
+    final_data[fmap['windGustSpeedNumUnit']] = 'm/s'
 
 # floor time to nearest hour
 dt = datetime.datetime.now()